-40%

Altronix ACM4 Access Power Controller, 4 Fused Relay Outputs, FAI, Board

$ 27.97

Availability: 100 in stock

Description

Designer Entryway
Welcome to Designer Entryway.
HAVE A QUESTION? -
Click to find out more
Feedback
Add to Favorites
Join Mailing List
CATEGORIES
Home
Home & Garden
Consumer Electronics
Business & Industrial
Computers/Tablets & Networking
More
Musical Instruments & Gear
eBay Motors
Cell Phones & Accessories
Cameras & Photo
Sporting Goods
Everything Else
Quick Delivery On All Items
100% Satisfaction Guaranteed
Money Back Guarantee
Product information
Altronix ACM4 Access Power Controller, 4 Fused Relay Outputs, FAI, Board
Click on the Image to Enlarge
Description
ACM4
Access Power Controller, 4 Fused Relay Outputs, FAI, Board
Altronix ACM4 converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes.
Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.
Input
12 to 24 volt AC or DC operation (setting not required), (0.4A @ 12volt, 0.2A @ 24 volt current consumption with all relays energized).
Power supply input options:
a) One (1) common power input (board and lock power).
b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power).
Four (4) Access Control System trigger inputs:
a) Four (4) normally open (NO) inputs.
b) Four (4) open collector sink inputs.
c) Any combination of the above.
Output
Four (4) independently controlled outputs:
a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
b) Four (4) dry form "C" 5A rated relay outputs
c) Any combination of the above
Four (4) auxiliary power outputs (unswitched).
Output ratings:
Fuses are rated 2.5A each.
Main fuse is rated at 10A.
Note: Total output current is determined by the power supply, not to exceed a maximum of 10A. total.
Features
Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit.
FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
Removable terminal blocks facilitate ease of installation.
Visual Indicators
Red LEDs indicate outputs are triggered (relays energized).
Green LED indicates FACP disconnect is triggered.
Electrical
Temperature:
Operating: 0° C to 49° C (32° F to 120° F).
Storage: - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.):
12VDC or 12VAC: 2 BTU/Hr.
24VDC or 24VAC: 3 BTU/Hr.
Payment
We accept Paypal as payment method.
Returns
Returns Accepted, Buyer, 30 Days, eBay Return Policy for Exchange or Money Back. All Products has to be in Original Packaging, not used, all seals intact and in a perfect condition.
Designer Entryway, LLC. only accept products returns from the returning party within 30 days of date of original purchase by the customer.
All Return Items Must Be returned to the address provided with the RMA document following the description of the specific defect ( i. e, reason for the return). However, failure to submit any item could impact the eligibility for credit. Upon receipt Designer Entryway, LLC. will assess the condition of the product and will determine if a defect exist in the material/product and will be result for final judgment to determine the final credit.
All Electronic items are to be inspected, in working conditions also they are subject to be inspected for matching Serial numbers from our records.
Contact us
To contact our Customer Service Team, simply click
Send Message
and our Customer Service team will be happy to assist.
We accept Paypal as payment method.
Returns Accepted, Buyer, 30 Days, eBay Return Policy for Exchange or Money Back. All Products has to be in Original Packaging, not used, all seals intact and in a perfect condition.
Designer Entryway, LLC. only accept products returns from the returning party within 30 days of date of original purchase by the customer.
All Return Items Must Be returned to the address provided with the RMA document following the description of the specific defect ( i. e, reason for the return). However, failure to submit any item could impact the eligibility for credit. Upon receipt Designer Entryway, LLC. will assess the condition of the product and will determine if a defect exist in the material/product and will be result for final judgment to determine the final credit.
All Electronic items are to be inspected, in working conditions also they are subject to be inspected for matching Serial numbers from our records.
To contact our Customer Service Team, simply click
Send Message
and our Customer Service team will be happy to assist.
Join Our Exclusive Newsletter For Up To Date News, Special Offers And New Arrivals
Sign up Now
Quick Links
Feedback
Add to Favorites
Contact us
Get in touch with us
Designer Entryway LLC
Kissimmee, Florida
Postal Code 34745
United States
Payment info
Copyright 2019
Designer Entryway LLC.
All Rights Reserved
Listing and template services provided by inkFrog