Altronix AL802ULADA NAC Power Supply 2 Class-A or 4 Class-B Outputs 8 AH 8 AMP

$ 316.79

Availability: 13 in stock
  • Model: AD802ULADA
  • Condition: New
  • Brand: Altronix

    Description

    Brand New.  Just in stock.  We will only accept the same exact unit back for replacement if defective.
    Altronix AL802ULADA is an extremely
    cost-effective
    voltage regulated remote NAC Power Extender. It may be connected to any 24-volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories.
    Input
    §
    Voltage:
    o
    120VAC, 60Hz, 4A.
    o
    Two (2) Class A or two (2) Class B inputs.
    o
    Two (2) NC dry contact trigger inputs.
    §
    Input Ratings (INP1 and INP2):
    o
    8-30VDC 6.5mA max from FACP.
    o
    12V 6.5mA, 24V 6.5mA from FACP.
    Output
    §
    Voltage:
    o
    24VDC power-limited outputs.
    §
    Current:
    o
    8A max. total alarm current.
    o
    2.5A max. current per output.
    §
    Auxiliary:
    o
    1A.
    §
    Other:
    o
    Thermal and short circuit protection with auto reset.
    o
    Filtered and regulated outputs.
    §
    Programmable Supervised Indicating Circuit Outputs:
    o
    Four (4) Class B, or TWO (2) Class A, or
    o
    One (1) Class A and Two (2) Class B.
    Back-up Battery (not included)
    o
    Type: Sealed lead acid or gel type.
    o
    Failover: Upon AC loss, instantaneous.
    Supervision
    o
    AC Failure: Form “C” contacts.
    o
    Battery: Form “C” contacts.
    Indicators (LED)
    o
    AC Power (Green): Input voltage is present.
    o
    DC Output (Red): Powered.
    o
    Logic Board (Red and Green): Output status.
    Special Features
    o
    2-wire horn/strobe Sync mode allows audible notification appliances (horns) and visual notification appliances (strobes) to be silenced/deactivated at the same time.
    o
    Sync protocols include Potter/Amseco, Gentex®, System Sensor®, and CooperWheelock®.
    o
    Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
    o
    Compatible with 12VDC or 24VDC fire panels.
    o
    Output loop supervision steered to Input 1 or Input 2.
    o
    Signal circuit trouble memory (helps identify intermittent loop problems).
    o
    Common trouble input and output for external trouble signals tie-in.
    o
    Ground fault detection.
    Temperature
    o
    Operating: 0° C to 49° C (32° F to 120° F).
    o
    Storage: - 20° C to 70°C ( - 4° F to 158° F).
    o
    Relative Humidity 85% +/- 5%.
    o
    BTU/Hr (approx.): 31 BTU/Hr.